All checks Housing Provisions 10.2.2
Shower waterproofing check
Shower walls are waterproofed to at least 1800 mm, and the joints and the floor have their own rules. Enter what you are installing to check it.
- Clause
- 10.2.2
- Code
- NCC 2022
- Drawn in
- mm
Checks
Pass. 3 of 3 checks within limits.
Shower walls waterproof to: Within the limit.
1800 mm
1800 mm or more10.2.2(1)(b)
Each side of wall joints: Within the limit.
40 mm
40 mm or more10.2.2(1)(c)
Flashing leg on the floor: Within the limit.
40 mm
40 mm or more10.2.3(3)
Shower floor: For information.
Waterproof
including any hob or step-down10.2.2(1)(a)
Floor outside the shower: For information.
Water resistant
concrete and fibre cement10.2.3
This checks the deemed-to-satisfy dimensions for houses (Class 1 and Class 10 buildings) in NCC 2022. State variations and your approved plans come first, and your certifier has the final say.
What the code asks for
- The shower floor is waterproof, including any hob or step-down. 10.2.2(1)(a)
- Shower walls are waterproof to at least 1800 mm above the floor substrate. 10.2.2(1)(b)
- Wall junctions and joints in the shower are waterproof for at least 40 mm either side. 10.2.2(1)(c)
- Wall and floor junctions and every penetration in the shower are waterproof. 10.2.2(1)
- A shower over a bath or spa follows the shower rules. 10.2.2
- Outside the shower, the floor is water resistant on concrete or fibre cement and waterproof on timber, particleboard or plywood. 10.2.3
- Wall and floor junctions outside the shower are waterproof. Where a flashing is used, its horizontal leg is at least 40 mm. 10.2.3(3)
- A wall beside a sink, basin or laundry tub that sits within 75 mm of it is water resistant to at least 150 mm above the fixture. 10.2.5(1)
Source: Part 10.2 of the ABCB Housing Provisions (NCC 2022). NCC 2025 keeps the 1800 mm wall height but rewords the joint rule, and the 40 mm figure is no longer in that clause. Read the 2025 text if your job is under it.
Questions people ask
How high does shower waterproofing need to go?
At least 1800 mm above the floor substrate, on the walls of the shower area. Measure from the substrate, not from the top of the tiles.
What is the difference between waterproof and water resistant?
Waterproof means moisture cannot get through. Water resistant means the material limits moisture movement and will not break down when it gets wet. The code lists which materials count as each.
Does South Australia have different rules?
Yes. South Australia varies this part of the code, including where floor wastes are needed. Other states can have variations too, so check the state filter on the ABCB site.