All checks Housing Provisions 10.5.1
Window size check for light and ventilation
A habitable room needs window glass equal to 10% of its floor area, and openings equal to 5%. Enter the room and window sizes to see if yours are big enough.
- Clause
- 10.5.1
- Code
- NCC 2022
- Drawn in
- mm
Checks
Pass. 2 of 2 checks within limits.
Floor area: For information.
14.00 m²
length × width
Natural light: Within the limit.
1.80 m²
1.40 m² of window needed10.5.1(2)
Ventilation: Within the limit.
0.90 m²
0.70 m² needed (5%)10.6.2(a)
This checks the deemed-to-satisfy dimensions for houses (Class 1 and Class 10 buildings) in NCC 2022. State variations and your approved plans come first, and your certifier has the final say.
What the code asks for
- Natural light: window glass of at least 10% of the floor area of the room. Measure the glass only, without frames and glazing bars. 10.5.1(2)(a)
- Roof lights count at 3% of the floor area, and you can mix them with windows in proportion. 10.5.1(2)(b)
- The window faces the sky, an open court, or an open verandah, carport or the like. 10.5.1(2)(a)
- A window relied on for light that faces the boundary of the next allotment is at least 900 mm from that boundary. 10.5.1(3)
- Ventilation: windows, doors or other openings that open to at least 5% of the floor area. 10.6.2(a)
- A room can borrow light or ventilation through an opening to the next room, if that opening and the next room's windows are big enough for both floor areas together. 10.5.1(4), 10.6.2(b)
- A bathroom, toilet, laundry or kitchen can be ventilated by an exhaust fan instead: 25 L/s for a bathroom or toilet and 40 L/s for a kitchen or laundry, discharging to outside air. 10.6.2(c), 10.8.2
- A bathroom, toilet, shower room, airlock or laundry without enough natural light needs one light fitting for every 16 m² of floor. 10.5.2
Source: Parts 10.5 and 10.6 of the ABCB Housing Provisions (NCC 2022). NCC 2025 keeps the 10%, 3% and 5% figures. It also exempts rooms such as pantries and walk-in robes from the ventilation rule.
Questions people ask
How big does a bedroom window need to be?
The glass has to be at least 10% of the floor area. A 3 m by 3.5 m bedroom is 10.5 m², so it needs 1.05 m² of glass, and 0.53 m² of window has to open.
Does a sliding door count?
Yes. Its glass counts toward light, and the part that slides open counts toward ventilation.
Do I measure the whole window or just the glass?
For light, just the glass. For ventilation, the size of the sash that opens.