All checks Housing Provisions 11.3.4
Balustrade height and gap check
A deck, balcony, landing or stair needs a barrier once you can fall 1 m or more. Enter the fall, the barrier height and the biggest gap to see if it passes.
- Clause
- 11.3.4
- Code
- NCC 2022
- Drawn in
- mm
Checks
Pass. 2 of 2 checks within limits.
Barrier required?: For information.
Yes
fall is 1500 mm11.3.3
Barrier height: Within the limit.
1000 mm
1000 mm or more11.3.4(2)
Biggest gap: Within the limit.
100 mm
under 125 mm11.3.4(4)
Nothing to climb: For information.
Not checked
only over a 4 m fall11.3.4(8)
This checks the deemed-to-satisfy dimensions for houses (Class 1 and Class 10 buildings) in NCC 2022. State variations and your approved plans come first, and your certifier has the final say.
What the code asks for
- A continuous barrier is required along a stair, ramp, floor, balcony, deck, verandah or path wherever it is possible to fall 1 m or more. 11.3.3(1)
- The barrier is at least 1 m above the floor of a deck, balcony or landing, and at least 865 mm above the nosings of a stair or the floor of a ramp. 11.3.4(2)
- On the inside edge of a stair landing, a barrier no more than 500 mm long can stay at 865 mm. 11.3.4(2)(b)
- No opening can let a 125 mm sphere through. On a stair, measure above the nosing line. 11.3.4(4)
- Where the barrier is fixed to the face of a deck or stair edge, the gap between that edge and the barrier is no more than 40 mm. 11.3.4(5)
- Where the fall is more than 4 m, nothing horizontal between 150 and 760 mm above the floor can help someone climb. 11.3.4(8)
- Wire barriers have their own tension and spacing tables. 11.3.6
- Glass barriers also have to meet the glazing rules, and every barrier has to carry the loads in AS/NZS 1170.1. 11.3.4(10)
- Pool fences follow a separate set of rules. H7D2
Source: Part 11.3 of the ABCB Housing Provisions (NCC 2022). The heights, the 125 mm rule and the 4 m climbing rule are the same in NCC 2025.
Questions people ask
How high does a balustrade need to be?
At least 1000 mm above the floor of a deck, balcony or landing, and at least 865 mm above the nosings on a stair or the floor of a ramp. Those are the minimums for houses, and they apply where the fall is 1 m or more.
Do I need a balustrade on a low deck?
Not under this rule if the deck is less than 1 m above the ground below it. Measure from the deck surface to the lowest ground beside it. Your approved plans can still ask for one.
Can I use horizontal wires or rails?
Yes where the fall is 4 m or less, as long as no gap lets a 125 mm sphere through. Wire has to be tensioned to the tables in clause 11.3.6. Over a 4 m fall, horizontal parts between 150 and 760 mm above the floor must not make the barrier climbable.