All checks Housing Provisions 11.3.7
Window fall protection check
Upstairs windows that open need protection once the fall outside is big enough: 2 m for bedrooms and 4 m for other rooms. Enter your heights to see what applies.
- Clause
- 11.3.7
- Code
- NCC 2022
- Drawn in
- mm
Checks
Fail. 1 of 1 check outside limits.
Protection required?: For information.
Yes
floor is 2900 mm up11.3.7(1)
Opening restricted: Outside the limit.
Fit a restrictor or a screen, or raise the opening to 1.7 m.
No device
under 125 mm, 250 N11.3.7(2)
This checks the deemed-to-satisfy dimensions for houses (Class 1 and Class 10 buildings) in NCC 2022. State variations and your approved plans come first, and your certifier has the final say.
What the code asks for
- In a bedroom, a window that opens needs protection where the floor is 2 m or more above the surface below. 11.3.7(1)
- If the lowest part of the opening is less than 1.7 m above the floor, fit a restrictor or a screen that stops a 125 mm sphere and resists a 250 N push. 11.3.7(2)
- If the restrictor or screen can be removed, unlocked or overridden, it needs a child resistant release, and the window also needs a barrier at least 865 mm high. 11.3.7(3)
- That barrier has no opening a 125 mm sphere fits through and nothing climbable between 150 and 760 mm above the floor. 11.3.7(4)
- In other rooms, where the floor is 4 m or more above the surface below, the opening needs a barrier at least 865 mm above the floor, with the same limits on gaps and climbable parts. 11.3.8
- A wall, or fixed glazing under the part that opens, counts as the barrier if it is high enough. 11.3.8
Source: Part 11.3 of the ABCB Housing Provisions (NCC 2022). The 2 m, 4 m, 1.7 m and 865 mm figures are the same in NCC 2025.
Questions people ask
How far can an upstairs bedroom window open?
If the floor is 2 m or more above the ground and the opening starts lower than 1.7 m above the floor, the gap has to stay under 125 mm, unless a screen is doing the same job.
Can the restrictor be one you can unlock?
Yes, so the window can still be opened fully when it needs to be. It has to have a child resistant release, such as a key or a two handed action, and the window then also needs an 865 mm barrier below the opening.
Does this apply to ground floor windows?
No. It starts once the floor inside is 2 m (bedrooms) or 4 m (other rooms) above the surface outside.