Build to Code

All checks Housing Provisions 10.3.1

Minimum ceiling height check

Rooms you live in need a ceiling at least 2.4 m high. Kitchens, corridors and wet rooms need 2.1 m, and sloping ceilings have their own rule. Pick the room and enter the height to check it.

24002400 min
Clause
10.3.1
Code
NCC 2022
Drawn in
mm
Pass1 of 1 check within limits
mm

Finished floor to finished ceiling. On a stair, straight up from the nosing line.

Checks

Pass. 1 of 1 check within limits.

  • Ceiling height: Within the limit.

    2400 mm

    2400 mm or more10.3.1(1)(a)

This checks the deemed-to-satisfy dimensions for houses (Class 1 and Class 10 buildings) in NCC 2022. State variations and your approved plans come first, and your certifier has the final say.

What the code asks for

  • Habitable rooms other than kitchens: 2.4 m. 10.3.1(1)(a)
  • Kitchens: 2.1 m. 10.3.1(1)(b)
  • Corridors and passages: 2.1 m. 10.3.1(1)(c)
  • Bathrooms, shower rooms, laundries, toilets, airlocks, pantries, storerooms, garages and car parking areas: 2.1 m. 10.3.1(1)(d)
  • A habitable room with a sloping ceiling, or with beams and bulkheads below the ceiling, needs 2.4 m over at least two-thirds of the floor area. In an attic that drops to 2.2 m. 10.3.1(1)(e)
  • A non-habitable room with a sloping ceiling needs 2.1 m over at least two-thirds of the floor area. 10.3.1(1)(e)
  • When you work out the floor area under a sloping ceiling, leave out any part where the ceiling is lower than 1.5 m. 10.3.1(2)
  • Stairs, ramps and landings: 2.0 m, measured straight up from the nosing line or the floor. 10.3.1(1)(f)

Source: Part 10.3 of the ABCB Housing Provisions (NCC 2022). The room heights are the same in NCC 2025.

Questions people ask

What is the minimum ceiling height for a bedroom?

2.4 m for a level ceiling. With a sloping ceiling it is 2.4 m over at least two-thirds of the floor area, or 2.2 m over two-thirds if the bedroom is in an attic.

What counts as a habitable room?

A room used for normal domestic activities: bedrooms, living and dining rooms, kitchens, studies, family rooms and the like. Bathrooms, laundries, toilets, pantries, walk-in robes, corridors and hallways are not habitable rooms.

Where do I measure to if there is no ceiling lining?

Measure from the floor to the underside of the floor or roof above.