Build to Code

All checks Housing Provisions 11.2.5

Door threshold and landing check

A door threshold more than 230 mm above the ground outside needs steps, and a door that opens onto a stair or ramp rising more than 570 mm needs a landing at least 750 mm long. Enter the sill height to see which applies.

doorinside900760
Clause
11.2.5
Code
NCC 2022
Drawn in
mm
Pass1 of 1 check within limits
mm

Door threshold down to the ground or floor outside it.

mm

Measured out from the door. Leave at 0 if there is none.

Door leads to

Checks

Pass. 1 of 1 check within limits.

  • Steps: For information.

    4 risers of 190 mm

    fewest that fit 115 to 19011.2.6

  • Landing length: Within the limit.

    900 mm

    750 mm or more11.2.5(1)(a)

  • Landing slope: For information.

    1:50 at most

    full width of the door11.2.5(1)

This checks the deemed-to-satisfy dimensions for houses (Class 1 and Class 10 buildings) in NCC 2022. State variations and your approved plans come first, and your certifier has the final say.

What the code asks for

  • A threshold more than 230 mm above the surface outside needs steps, with risers and goings that meet the stair limits. 11.2.6
  • A landing is needed where the door opens onto a stair or ramp that changes level by more than 570 mm, or by more than 3 risers. 11.2.5(1)(c)
  • The landing is at least 750 mm long, runs the full width of the doorway and is no steeper than 1:50. 11.2.5(1)
  • Where a landing changes direction, its length is measured 500 mm in from the inside edge. 11.2.5(1)(a)
  • On a stair that only serves an attic, storeroom or similar room, the landing can be 600 mm long. 11.2.5(2)

Source: Part 11.2 of the ABCB Housing Provisions (NCC 2022). The 230 mm, 570 mm and 750 mm figures are the same in NCC 2025.

Questions people ask

How big a step can I have at a door?

Up to 230 mm without building steps. Over that, the door needs steps with risers of 115 to 190 mm.

Do I need a landing outside my back door?

Only if the drop from the sill to the ground is more than 570 mm, or the steps have more than 3 risers. Then the door needs a landing at least 750 mm long before the first step down.

Does the landing need a balustrade?

It does once you can fall 1 m or more from it. Use the balustrade check for the height and gaps.

Related checks